143 lines
5.1 KiB
Python
143 lines
5.1 KiB
Python
|
"""
|
||
|
Cooperative implementation of special cases of :func:`signal.signal`.
|
||
|
|
||
|
This module is designed to work with libev's child watchers, as used
|
||
|
by default in :func:`gevent.os.fork` Note that each ``SIGCHLD``
|
||
|
handler will be run in a new greenlet when the signal is delivered
|
||
|
(just like :class:`gevent.hub.signal`)
|
||
|
|
||
|
The implementations in this module are only monkey patched if
|
||
|
:func:`gevent.os.waitpid` is being used (the default) and if
|
||
|
:const:`signal.SIGCHLD` is available; see :func:`gevent.os.fork` for
|
||
|
information on configuring this not to be the case for advanced uses.
|
||
|
|
||
|
.. versionadded:: 1.1b4
|
||
|
.. versionchanged:: 1.5a4
|
||
|
Previously there was a backwards compatibility alias
|
||
|
``gevent.signal``, introduced in 1.1b4, that partly shadowed this
|
||
|
module, confusing humans and static analysis tools alike. That alias
|
||
|
has been removed. (See `gevent.signal_handler`.)
|
||
|
"""
|
||
|
|
||
|
from __future__ import absolute_import
|
||
|
|
||
|
from gevent._util import _NONE as _INITIAL
|
||
|
from gevent._util import copy_globals
|
||
|
|
||
|
import signal as _signal
|
||
|
|
||
|
__implements__ = []
|
||
|
__extensions__ = []
|
||
|
|
||
|
|
||
|
_child_handler = _INITIAL
|
||
|
|
||
|
_signal_signal = _signal.signal
|
||
|
_signal_getsignal = _signal.getsignal
|
||
|
|
||
|
|
||
|
def getsignal(signalnum):
|
||
|
"""
|
||
|
Exactly the same as :func:`signal.getsignal` except where
|
||
|
:const:`signal.SIGCHLD` is concerned.
|
||
|
|
||
|
For :const:`signal.SIGCHLD`, this cooperates with :func:`signal`
|
||
|
to provide consistent answers.
|
||
|
"""
|
||
|
if signalnum != _signal.SIGCHLD:
|
||
|
return _signal_getsignal(signalnum)
|
||
|
|
||
|
global _child_handler
|
||
|
if _child_handler is _INITIAL:
|
||
|
_child_handler = _signal_getsignal(_signal.SIGCHLD)
|
||
|
|
||
|
return _child_handler
|
||
|
|
||
|
|
||
|
def signal(signalnum, handler):
|
||
|
"""
|
||
|
Exactly the same as :func:`signal.signal` except where
|
||
|
:const:`signal.SIGCHLD` is concerned.
|
||
|
|
||
|
.. note::
|
||
|
|
||
|
A :const:`signal.SIGCHLD` handler installed with this function
|
||
|
will only be triggered for children that are forked using
|
||
|
:func:`gevent.os.fork` (:func:`gevent.os.fork_and_watch`);
|
||
|
children forked before monkey patching, or otherwise by the raw
|
||
|
:func:`os.fork`, will not trigger the handler installed by this
|
||
|
function. (It's unlikely that a SIGCHLD handler installed with
|
||
|
the builtin :func:`signal.signal` would be triggered either;
|
||
|
libev typically overwrites such a handler at the C level. At
|
||
|
the very least, it's full of race conditions.)
|
||
|
|
||
|
.. note::
|
||
|
|
||
|
Use of ``SIG_IGN`` and ``SIG_DFL`` may also have race conditions
|
||
|
with libev child watchers and the :mod:`gevent.subprocess` module.
|
||
|
|
||
|
.. versionchanged:: 1.2a1
|
||
|
If ``SIG_IGN`` or ``SIG_DFL`` are used to ignore ``SIGCHLD``, a
|
||
|
future use of ``gevent.subprocess`` and libev child watchers
|
||
|
will once again work. However, on Python 2, use of ``os.popen``
|
||
|
will fail.
|
||
|
|
||
|
.. versionchanged:: 1.1rc2
|
||
|
Allow using ``SIG_IGN`` and ``SIG_DFL`` to reset and ignore ``SIGCHLD``.
|
||
|
However, this allows the possibility of a race condition if ``gevent.subprocess``
|
||
|
had already been used.
|
||
|
"""
|
||
|
if signalnum != _signal.SIGCHLD:
|
||
|
return _signal_signal(signalnum, handler)
|
||
|
|
||
|
# TODO: raise value error if not called from the main
|
||
|
# greenlet, just like threads
|
||
|
|
||
|
if handler != _signal.SIG_IGN and handler != _signal.SIG_DFL and not callable(handler):
|
||
|
# exact same error message raised by the stdlib
|
||
|
raise TypeError("signal handler must be signal.SIG_IGN, signal.SIG_DFL, or a callable object")
|
||
|
|
||
|
old_handler = getsignal(signalnum)
|
||
|
global _child_handler
|
||
|
_child_handler = handler
|
||
|
if handler in (_signal.SIG_IGN, _signal.SIG_DFL):
|
||
|
# Allow resetting/ignoring this signal at the process level.
|
||
|
# Note that this conflicts with gevent.subprocess and other users
|
||
|
# of child watchers, until the next time gevent.subprocess/loop.install_sigchld()
|
||
|
# is called.
|
||
|
from gevent.hub import get_hub # Are we always safe to import here?
|
||
|
_signal_signal(signalnum, handler)
|
||
|
get_hub().loop.reset_sigchld()
|
||
|
return old_handler
|
||
|
|
||
|
|
||
|
def _on_child_hook():
|
||
|
# This is called in the hub greenlet. To let the function
|
||
|
# do more useful work, like use blocking functions,
|
||
|
# we run it in a new greenlet; see gevent.hub.signal
|
||
|
if callable(_child_handler):
|
||
|
# None is a valid value for the frame argument
|
||
|
from gevent import Greenlet
|
||
|
greenlet = Greenlet(_child_handler, _signal.SIGCHLD, None)
|
||
|
greenlet.switch()
|
||
|
|
||
|
|
||
|
import gevent.os
|
||
|
|
||
|
if 'waitpid' in gevent.os.__implements__ and hasattr(_signal, 'SIGCHLD'):
|
||
|
# Tightly coupled here to gevent.os and its waitpid implementation; only use these
|
||
|
# if necessary.
|
||
|
gevent.os._on_child_hook = _on_child_hook
|
||
|
__implements__.append("signal")
|
||
|
__implements__.append("getsignal")
|
||
|
else:
|
||
|
# XXX: This breaks test__all__ on windows
|
||
|
__extensions__.append("signal")
|
||
|
__extensions__.append("getsignal")
|
||
|
|
||
|
__imports__ = copy_globals(_signal, globals(),
|
||
|
names_to_ignore=__implements__ + __extensions__,
|
||
|
dunder_names_to_keep=())
|
||
|
|
||
|
__all__ = __implements__ + __extensions__
|