ar71xx: rb91x: fix pll_1000 value for eth0 to avoid packet loss
When the RB91x device uses a GbE link the connection suffers from packet loss: root@OpenWrt:/# ping 192.168.1.254 -s 65507 -c 20 -q PING 192.168.1.254 (192.168.1.254): 65507 data bytes --- 192.168.1.254 ping statistics --- 20 packets transmitted, 9 packets received, 55% packet loss round-trip min/avg/max = 4.570/4.815/4.999 ms Using a different PLL value fixes the issue. root@OpenWrt:/# ping 192.168.1.254 -s 65507 -c 100 -q PING 192.168.1.254 (192.168.1.254): 65507 data bytes --- 192.168.1.254 ping statistics --- 100 packets transmitted, 100 packets received, 0% packet loss round-trip min/avg/max = 4.449/5.413/13.870 ms Signed-off-by: Gabor Juhos <juhosg@openwrt.org> SVN-Revision: 39642
This commit is contained in:
parent
d19b868b12
commit
4e0309630b
@ -156,6 +156,7 @@ static void __init rb711gr100_setup(void)
|
||||
ath79_init_mac(ath79_eth0_data.mac_addr, ath79_mac_base, 0);
|
||||
ath79_eth0_data.phy_if_mode = PHY_INTERFACE_MODE_RGMII;
|
||||
ath79_eth0_data.phy_mask = BIT(0);
|
||||
ath79_eth0_pll_data.pll_1000 = 0x02000000;
|
||||
|
||||
ath79_register_eth(0);
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user