178 lines
4.0 KiB
Bash
178 lines
4.0 KiB
Bash
|
#!/bin/sh
|
||
|
#
|
||
|
# Copyright (C) 2012 OpenWrt.org
|
||
|
#
|
||
|
|
||
|
. /lib/functions.sh
|
||
|
. /lib/ar71xx.sh
|
||
|
|
||
|
get_mtd_part_size() {
|
||
|
local part_name=$1
|
||
|
local first dev size erasesize name
|
||
|
while read dev size erasesize name; do
|
||
|
name=${name#'"'}; name=${name%'"'}
|
||
|
if [ "$name" = "$part_name" ]; then
|
||
|
echo $((0x$size))
|
||
|
break
|
||
|
fi
|
||
|
done < /proc/mtd
|
||
|
}
|
||
|
|
||
|
get_magic_at() {
|
||
|
local mtddev=$1
|
||
|
local pos=$2
|
||
|
dd bs=1 count=2 skip=$pos if=$mtddev 2>/dev/null | hexdump -v -n 4 -e '1/1 "%02x"'
|
||
|
}
|
||
|
|
||
|
dir825b_is_caldata_valid() {
|
||
|
local mtddev=$1
|
||
|
local magic
|
||
|
|
||
|
magic=$(get_magic_at $mtddev 4096)
|
||
|
[ "$magic" != "a55a" ] && return 0
|
||
|
|
||
|
magic=$(get_magic_at $mtddev 20480)
|
||
|
[ "$magic" != "a55a" ] && return 0
|
||
|
|
||
|
return 1
|
||
|
}
|
||
|
|
||
|
dir825b_copy_caldata() {
|
||
|
local cal_src=$1
|
||
|
local cal_dst=$2
|
||
|
local mtd_src
|
||
|
local mtd_dst
|
||
|
local md5_src
|
||
|
local md5_dst
|
||
|
|
||
|
mtd_src=$(find_mtd_part $cal_src)
|
||
|
[ -z "$mtd_src" ] && {
|
||
|
echo "no $cal_src partition found"
|
||
|
return 1
|
||
|
}
|
||
|
|
||
|
mtd_dst=$(find_mtd_part $cal_dst)
|
||
|
[ -z "$mtd_dst" ] && {
|
||
|
echo "no $cal_dst partition found"
|
||
|
return 1
|
||
|
}
|
||
|
|
||
|
dir825b_is_caldata_valid "$mtd_src" && {
|
||
|
echo "no valid calibration data found in $cal_src"
|
||
|
return 1
|
||
|
}
|
||
|
|
||
|
dir825b_is_caldata_valid "$mtd_dst" && {
|
||
|
echo "Copying calibration data from $cal_src to $cal_dst..."
|
||
|
dd if="$mtd_src" 2>/dev/null | mtd -q -q write - "$cal_dst"
|
||
|
}
|
||
|
|
||
|
md5_src=$(md5sum "$mtd_src") && md5_src="${md5_src%% *}"
|
||
|
md5_dst=$(md5sum "$mtd_dst") && md5_dst="${md5_dst%% *}"
|
||
|
|
||
|
[ "$md5_src" != "$md5_dst" ] && {
|
||
|
echo "calibration data mismatch $cal_src:$md5_src $cal_dst:$md5_dst"
|
||
|
return 1
|
||
|
}
|
||
|
|
||
|
return 0
|
||
|
}
|
||
|
|
||
|
dir825b_do_upgrade_combined() {
|
||
|
local fw_part=$1
|
||
|
local fw_file=$2
|
||
|
local fw_mtd=$(find_mtd_part $fw_part)
|
||
|
local fw_length=0x$(dd if="$fw_file" bs=2 skip=1 count=4 2>/dev/null)
|
||
|
local fw_blocks=$(($fw_length / 65536))
|
||
|
|
||
|
if [ -n "$fw_mtd" ] && [ ${fw_blocks:-0} -gt 0 ]; then
|
||
|
local append=""
|
||
|
[ -f "$CONF_TAR" -a "$SAVE_CONFIG" -eq 1 ] && append="-j $CONF_TAR"
|
||
|
|
||
|
sync
|
||
|
dd if="$fw_file" bs=64k skip=1 count=$fw_blocks 2>/dev/null | \
|
||
|
mtd $append write - "$fw_part"
|
||
|
fi
|
||
|
}
|
||
|
|
||
|
dir825b_check_image() {
|
||
|
local magic="$(get_magic_long "$1")"
|
||
|
local fw_mtd=$(find_mtd_part "firmware_orig")
|
||
|
|
||
|
case "$magic" in
|
||
|
"27051956")
|
||
|
;;
|
||
|
"43493030")
|
||
|
local md5_img=$(dd if="$1" bs=2 skip=9 count=16 2>/dev/null)
|
||
|
local md5_chk=$(dd if="$1" bs=64k skip=1 2>/dev/null | md5sum -); md5_chk="${md5_chk%% *}"
|
||
|
local fw_len=$(dd if="$1" bs=2 skip=1 count=4 2>/dev/null)
|
||
|
local fw_part_len=$(get_mtd_part_size "firmware")
|
||
|
|
||
|
if [ -z "$fw_mtd" ]; then
|
||
|
ask_bool 0 "Do you have a backup of the caldata partition?" || {
|
||
|
echo "Warning, please make sure that you have a backup of the caldata partition."
|
||
|
echo "Once you have that, use 'sysupgrade -i' for upgrading to the 'fat' firmware."
|
||
|
return 1
|
||
|
}
|
||
|
fi
|
||
|
|
||
|
if [ -z "$md5_img" -o -z "$md5_chk" ]; then
|
||
|
echo "Unable to get image checksums. Maybe you are using a streamed image?"
|
||
|
return 1
|
||
|
fi
|
||
|
|
||
|
if [ "$md5_img" != "$md5_chk" ]; then
|
||
|
echo "Invalid image. Contents do not match checksum (image:$md5_img calculated:$md5_chk)"
|
||
|
return 1
|
||
|
fi
|
||
|
|
||
|
fw_len=$((0x$fw_len))
|
||
|
fw_part_len=${fw_part_len:-0}
|
||
|
|
||
|
if [ $fw_part_len -lt $fw_len ]; then
|
||
|
echo "The upgrade image is too big (size:$fw_len available:$fw_part_len)"
|
||
|
return 1
|
||
|
fi
|
||
|
;;
|
||
|
*)
|
||
|
echo "Unsupported image format."
|
||
|
return 1
|
||
|
;;
|
||
|
esac
|
||
|
|
||
|
return 0
|
||
|
}
|
||
|
|
||
|
platform_do_upgrade_dir825b() {
|
||
|
local magic="$(get_magic_long "$1")"
|
||
|
local fw_mtd=$(find_mtd_part "firmware_orig")
|
||
|
|
||
|
case "$magic" in
|
||
|
"27051956")
|
||
|
if [ -n "$fw_mtd" ]; then
|
||
|
# restore calibration data before downgrading to
|
||
|
# the normal image
|
||
|
dir825b_copy_caldata "caldata" "caldata_orig" || {
|
||
|
echo "unable to restore calibration data"
|
||
|
exit 1
|
||
|
}
|
||
|
PART_NAME="firmware_orig"
|
||
|
else
|
||
|
PART_NAME="firmware"
|
||
|
fi
|
||
|
default_do_upgrade "$ARGV"
|
||
|
;;
|
||
|
"43493030")
|
||
|
if [ -z "$fw_mtd" ]; then
|
||
|
# backup calibration data before upgrading to the
|
||
|
# fat image
|
||
|
dir825b_copy_caldata "caldata" "caldata_copy" || {
|
||
|
echo "unable to backup calibration data"
|
||
|
exit 1
|
||
|
}
|
||
|
fi
|
||
|
dir825b_do_upgrade_combined "firmware" "$ARGV"
|
||
|
;;
|
||
|
esac
|
||
|
}
|